Brothers Industrial Ltd
|
Price: | 4.0~7.0 USD |
Payment Terms: | T/T |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Europe leakage protective plug
Using advanced intergrated circuit
small size,nice shape ,high senditivity
esay to use
This leakage protection plugs have got the approval of CE, it can be used in 240VAC single-phase circuit, widely used for home appliances----electric water heater, microwave oven, induction cooker, TV, fridge, washer, hair drier, electric iron, cleaner, electric pump, cropper, hand-held electric tools and other appliances.
Body case employs high-performance polycarbonate materials,beautiful appearance ,super waterproof function, high reliability, anti-jamming ,high temperature no crack, no deformation, safe and reliable.
LBC series leajage current protective plug ia kind of terminal leakage current protective machine .Using advanced intergrated circuit,small size,nice shape ,high senditivity,esay to use,great stability and so on .it applies to water heater ,washing machinery,disinfector,hand electric tools and small appliance.it makes electrical equipment safereto use.
specifications | ||||||
Type | Rated Voltage | Rated Current | Rated leakage action current | Rated Hold Current | Breaking Time | Electrical Life |
(V) | (A) | (mA) | (mA) | (S) | (times) | |
LBC- | 230 | 6,10, 16 | 6,10,15,(30) | 5(15) | ≤0.1 | 5000 |
Feature:
The adaptor is portable so can be moved between socket outlets.
Simplyplug your portable tool into the adaptor and you are provided with earth leakageprotection
Test and reset buttons.
The body case is madefrom high-performance polycarbonate, safety & reliable.
CE certificatd Europe leakage protective plug
USE:
1, test: press the " RESET" button, after the hand loosens the indicator light; press the " TEST" button, a plug release, lights out, expressed in normal, can be put into use. Remember: each time before use should be tested!
2, use: press the "RESET" button, to be locked after letting go, bright lights, can be used.
3, such as fault: press the " TEST " button, no power; or press the "RESET" key can't lock ( pull the plug " RESET" button can be pressed, then insert into the socket, " RESET " jumps ) showed leakage protection plug or appliance has fault, should stop using, required by the professional maintenance personnel repair.
The matters needing attention:
1, prohibit the unauthorized removal, otherwise the consequence is proud.
2, no leakage protector is directly contacted with water or directly spray.
3, the earth leakage protective device on the short circuit or the human body at the same time reach zero phase line has no protective function.
Reminder: if the user need to cut off power to use, without the need to pull the plug, only need to " test" button, the power is completely cut off; the need to restore power supply, press the " reset" button. If I press the "test" button after releasing, please press the " reset" button, such as being able to return to normal work, please rest assured that the use of.